DFARS Readiness Checklists and guides for DFARS readiness.

Guides / November 07, 2026

How Do I Handle a DFARS Requirement When My Subcontractor Uses a Different Cloud?

Diagram of a prime contractor, a subcontractor, and a separate cloud service with checks between them

Your subcontractor stores your drawings in a cloud you have never used. The drawings are covered defense information. The rule follows the data, not the logo on the cloud. You must check their cloud before the data moves.

CDI means covered defense information. It is the CUI the DoD gives you, or that you create for the DoD. CUI means Controlled Unclassified Information. DoD means Department of Defense.

What the clause asks of you

DFARS 252.204-7012 sets four duties. DFARS means Defense Federal Acquisition Regulation Supplement. The duties are safeguard the data, report incidents, use a sound cloud, and flow the clause down. The clause binds the prime and every subcontractor that touches CDI.

The flow down duty sits in paragraph (m). You must put the clause in the subcontract without change, except for naming the parties. The subcontractor then carries the same duties you carry. Your own compliance does not cover them. Their cloud is their duty, and your duty is to check it.

What their cloud must meet

Any cloud that stores, processes, or transmits CDI must meet security rules equal to the FedRAMP Moderate baseline. FedRAMP is the Federal Risk and Authorization Management Program. The bar sits in paragraph (b)(2)(ii)(D) of the clause.

A cloud with a full FedRAMP Moderate authorization meets the bar. A cloud without one can still qualify through a FedRAMP equivalency check. A FedRAMP recognized 3PAO must confirm full compliance with the Moderate baseline. 3PAO means third party assessment organization. Partial compliance does not count.

Ask the subcontractor for the proof. The proof is the authorization listing, or the 3PAO letter plus the assessment report. Check the listing on the FedRAMP Marketplace. Check the date on the letter. If the proof is missing, the data stays with you.

What to check before you share data

Check four things, in order. First, the clause is in the subcontract. Second, the subcontractor runs the NIST SP 800-171 safeguards. Third, their cloud meets the FedRAMP Moderate bar. Fourth, they know the incident rules.

The incident rules matter most in a crisis. The subcontractor must report a cyber incident to the DoD within 72 hours. They must also give you the incident report number. Your incident plan should name who calls whom, and in what order.

If the subcontractor cannot meet the bar, do not share CDI with them. Find a cloud that meets the bar, or find another subcontractor. Sharing first and checking later puts your contract at risk.

What to do this week

Ask your subcontractor which cloud holds your CDI. Ask for the FedRAMP listing or the 3PAO letter. Read the subcontract for the flow down clause. Then write the incident call list into your plan.

Sources

Next step

Want your DFARS evidence gathered from live systems, not by hand? See how PolicyCortex collects it automatically.